Product Overview
The Portable Ultrasonic Flow Meter for Water is a clamp-on transit-time device for non-intrusive liquid flow measurement.
Technical Specifications
|
Parameter |
Specification / Value |
Tolerance / Limits |
|
Measurement Performance |
||
|
Measurement Principle |
Transit-time ultrasonic method |
N/A |
|
Flow Velocity Range |
±0.01 to ±12 m/s (bidirectional) |
±0.005 m/s threshold |
|
Measurement Accuracy |
±1.0% of reading (>0.2 m/s) |
±0.2% (calibrated) |
|
Repeatability |
0.2% |
±0.05% |
|
Pipe Size Range |
DN15–DN100 / DN50–DN700 / DN300–6000 |
±1 mm inner diameter input |
|
Compatible Pipe Materials |
Steel, stainless steel, cast iron, PVC, HDPE, copper, FRP |
Liner thickness ±0.1 mm |
|
Fluid Type |
Water, wastewater, river, chilled/hot water |
Solids <10,000 ppm |
|
Electrical & Power |
||
|
Power Supply |
3.7V rechargeable battery; 100–240 VAC charger |
±10% voltage |
|
Battery Life |
≥14 hours continuous operation |
±1 hour |
|
Data Logging |
Internal memory / 32 GB SD card |
Time sync ±1 sec/day |
|
Signal Inputs & Outputs |
||
|
Analog Output |
4–20 mA (≤750 Ω load) |
±0.1% FS |
|
Digital Communication |
USB Type-C / RS485 Modbus RTU |
±1% baud stability |
|
Pulse Output |
OCT pulse (0–5 V) |
±5 μs |
|
Analog Input |
Dual 4–20 mA / PT1000 support |
±0.1°C |
|
Environmental & Physical |
||
|
Operating Temperature |
Transmitter: −20°C to +60°C / Sensors: −30°C to +90°C |
±2°C |
|
Protection Rating |
IP65 (main unit) / IP68 (transducers, ≤2 m) |
IEC 60529 |
|
Dimensions |
210 × 100 × 35 mm |
±2 mm |
|
Weight |
0.65 kg (with battery) |
±0.05 kg |
Technical Advantages & Features
Acoustic Matching Technology
Transducer signals are adjusted for different pipe wall conditions through factory calibration.
Zero-Point Stabilization
DSP reduces zero drift under low-flow conditions.
Traceable Calibration
Each unit is calibrated using multi-point wet calibration against reference standards.
Dual-Processor Architecture
One processor handles acoustic measurement, another handles user interface.
Compliance, Calibration & Certification
|
Category |
Regulatory Standard / Framework |
Factory Alignment & Verification |
|
Quality Management |
ISO 9001 Certified Facility |
Production follows audited quality control system |
|
Electrical Safety |
CE Compliance |
Electronics meet EU EMC and low-voltage directives |
|
Flow Traceability |
NIST Traceable Standards |
Calibration referenced to certified master meters |
|
Hazardous Areas |
IEC Ex-Proof Standards |
Selected models support intrinsic safety design |
|
Environmental Safety |
RoHS Compliance |
Restricted use of hazardous substances in components |
|
Testing Methodology |
VDI/VDE 2640 Guidelines |
Ultrasonic testing follows recognized procedures |
Manufacturing Capabilities & QC
Manufacturing Capabilities
Multi-Axis Milling Centers
CNC machines process acoustic wedges with controlled dimensional tolerances.
Class 10,000 Cleanrooms
Piezoelectric crystal bonding is done in controlled cleanroom environments.
Laser Welding Stations
Laser welding seals transducer housings for hermetic joints.
High-Capacity Assembly Lines
Scalable manufacturing layouts support flexible batch production volumes.
Quality Control (QC)
Acoustic Impedance Analysis
Each transducer crystal undergoes frequency testing prior to final component assembly.
Hydrostatic Pressure Testing
Sensor enclosures face high-pressure water submersions to verify structural sealing.
X-Ray Solder Inspection
Automated X-ray inspection (AXI) detects subsurface solder joint anomalies.
48-Hour Burn-In
Electronics undergo thermal aging before shipment.
Complete Kit Package & Options
|
Item Category |
Component Name |
Included / Optional |
Standard Quantity / Provision |
|
Standard Kit |
Handheld Transmitter |
Included |
1 unit |
|
M2/S2 Transducers |
Included |
1 pair |
|
|
Signal Cables (5 m) |
Included |
2 pcs |
|
|
Clamps / Mounting Chains |
Included |
1 set |
|
|
Coupling Compound |
Included |
1 bottle |
|
|
Carrying Case |
Included |
1 unit |
|
|
Optional |
Large Pipe Transducers |
Optional |
Available on request |
|
High-Temperature Transducers |
Optional |
Available on request |
|
|
Ultrasonic Thickness Gauge |
Optional |
Available on request |
Industry Applications
|
Application Field |
Typical use |
|
Municipal Water |
Clamped on water mains for bulk flow measurement |
|
HVAC & Cooling |
Installed on chilled water pipes for energy balancing |
|
Industrial Process |
Used on process pipelines for consumption monitoring |
|
Wastewater Control |
Installed on effluent discharge lines |
|
Building Management |
Used for multi-point sub-metering checks |
|
Agricultural Irrigation |
Mounted on distribution pipelines for flow tracking |
FAQ
|
HNF110-A Handheld Ultrasonic Flow Meter Parameters |
|
|
Specific Parameters |
Value / Description |
|
Measurement Principle |
When an ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in the propagation time, and this change in propagation time is proportional to the flow rate of the liquid. At zero flow, the time required for the two sensors to emit and receive sound waves is exactly the same (the only technology that can actually measure zero flow), and when the liquid flows, the transmission time of the sound wave in the counter-flow direction is greater than that in the downstream direction. |
|
Nominal Diameter Range |
15mm-6000mm |
|
Measurement Accuracy |
Flow ±1%, linearity ±0.5%; Heat ±2%; P3 accuracy calibrated to ±0.5% as per customer requirements |
|
Flow Rate |
0~±10m/s |
|
Medium Temperature Range |
Normal temperature type: -30~90℃; High temperature type: -30~160℃ |
|
Ambient Temperature Range |
Host: -20~60℃; Sensor: -20~60℃ |
|
Measuring Medium |
Water, sea water, industrial wastewater, acid-base solutions, alcohol, beer, various oils, and other single homogeneous liquids capable of conducting ultrasound |
|
Transmitter Housing Material |
Steel, stainless steel, cast iron, PVC, copper, aluminum, and all other dense pipes, allowing for lining |
|
Display |
6x12 Chinese or 6x25 Western characters backlight LCD display, supports five languages: Chinese, English, Italian, Spanish, and Turkish, 16+4 tactile keyboard |
|
Communication Interface |
Type-C interface, can connect to computers or charge |
|
Communication Protocol |
RS485, Modbus Protocol |
|
Data Storage |
Built-in data logger that can store 16,500 sets of measurement data |
|
Signal Output |
Customized to customer requirements |
|
Power Supply |
Built-in high-capacity NiMH rechargeable battery, also can use three alkaline batteries, supports a continuous measurement for over 10 hours, with a power adapter, uninterrupted measurement can be achieved |
|
Wetted Parts Material |
Flame Retardant ABS |
|
External Dimensions |
208*102*48 |
Hot Tags: portable ultrasonic flow meter for water, China portable ultrasonic flow meter for water manufacturers, suppliers, factory, coriolis gas flow meter, Diesel turbine flow meter, DN25 Flow Switch, Piston Type Flow Switch, portable ultrasonic flow meter with clamp, rotor flow sensor






