Product Overview
The Metal Tube Flow Meter is a variable area instrument for measuring liquid and gas flow.
Technical Specifications
|
Category |
Parameter |
Specification |
Reference |
|
Performance |
Accuracy Class |
Standard: Class 1.5Optional: Class 1.0 / Class 2.5 |
±1.5% FS±1.0% FS / ±2.5% FS |
|
Turndown Ratio |
Standard: 10:1Optional: 12:1 |
Optional |
|
|
Repeatability |
≤0.5% |
Max. ±0.5% |
|
|
Flow Range (Water) |
0.0025–100 m³/h |
By size |
|
|
Flow Range (Air) |
0.07–3000 m³/h |
By size |
|
|
Process & Physical |
Nominal Diameter |
DN15–DN150 (1/2"–6") |
±1 mm |
|
Pressure Rating |
DN15–DN50: ≤4.0 MPaDN80–DN150: ≤1.6 MPaOptional: ≤16 MPa |
1.5 × PN Test |
|
|
Process Temperature |
Standard: -80°C to +200°CHigh-Temperature Jacket: up to +400°C |
Optional |
|
|
Ambient Temperature |
Pointer: -40°C to +85°CDigital: -20°C to +70°C |
Operating Limit |
|
|
Fluid Viscosity |
DN15: ≤30 mPa·sDN25–DN100: ≤250 mPa·s |
Reference |
|
|
Electrical & Signals |
Power Supply |
Mechanical: No PowerRemote: 24 VDC (12–36 VDC)Battery: 3.6 V |
±10% |
|
Output Signal |
4–20 mAPulse Output |
±0.1% FS |
|
|
Digital Communication |
HARTModbus RS485Profibus-PA |
Optional |
|
|
Alarm Output |
High / Low Limit Switches(NAMUR or Relay) |
±1% FS |
|
|
Mechanical |
Wetted Materials |
316 / 316L SSPTFEHastelloyTitanium |
ASTM / EN |
|
Process Connection |
Flange (ANSI / DIN / JIS)ThreadedTri-Clamp |
±1.5 mm |
|
|
Protection Rating |
IP65 / IP67 |
IEC 60529 |
|
|
Hazardous Area Approval |
Ex d IIC T6 GbEx ia IIC T6 Ga |
ATEX / IECEx |
International Certifications & Compliance
|
Standard Type |
Compliance Scope |
|
Hazardous Area |
ATEX / IECEx |
|
Quality Assurance |
ISO 9001 |
|
European Conformity |
CE Mark |
|
Metrology & Sizing |
Traceable Calibration Certificate |
|
Material Traceability |
EN 10204 3.1 Material Certificate |
In-House Calibration & Quality Control
1.Flow Calibration: Conducted on water or gas calibration systems before shipment.
2.Pressure Integrity: Hydrostatic pressure testing confirms pressure containment at specified ratings.
3.Nondestructive Testing: Dye penetrant and radiographic testing are available for specified welded components.
4.Dimensional Inspection: Dimensional inspections confirm flange dimensions and assembly tolerances.
5.Signal Verification: Signal output testing confirms proper operation across the measurement range.
6.Traceability Logging: Production records link test reports with material traceability documents.
Customization
Meter Configuration: Size, material, pressure rating, and output options can be specified during ordering.
Thermal Management Jackets: Optional steam or hot oil jackets help maintain fluid temperature during operation.
Indication Housing Variants: Aluminum or stainless steel housings are available for different installation environments.
Process Connection Adaptability: Flange connections are available to international standards or project requirements.
Applications
|
Industry Sector |
Typical Applications |
|
Chemical & Petrochemical |
Chemical dosing, acid transfer, hydrocarbon processing, and process fluid measurement. |
|
Oil & Gas Operations |
Production separators, refinery blending, pipeline flow measurement, and chemical injection lines. |
|
Power Generation |
Boiler feedwater systems, cooling water circulation, condensate recovery, and utility processes. |
|
Water Treatment |
Flocculant dosing, wastewater treatment, sludge processing, desalination systems, and water distribution networks. |
FAQ
|
HNF50 Metal Float Flow Meter |
|
|
Specific Parameters |
Value / Description |
|
Measurement Principle |
Adopting the variable area measurement principle, it is suitable for flow measurement of liquids and gases. All metal structures, including pointer type, electric remote transmission type, corrosion-resistant type, high-pressure type, jacket type, and explosion-proof type. It is equipped with standard analog signal output and local indication. |
|
Nominal Diameter Range |
DN15 ~ DN150 |
|
Wetted Parts Material |
The measuring tube and float materials are optional: 304 (0Cr18Ni9), 316 (0Cr18Ni12Mo2Ti), 316L (00Cr17Ni14Mo2), Hastelloy B/C, Titanium/Titanium Alloy, PTFE Lined. Hygienic surface roughness < 0.8Ra |
|
Connection Method |
Standard type: Flange connection (standard GB/T9119-2000), flange clamp connection method can also be provided. |
|
Maximum Measurement Error |
Accuracy ≤±1.5% FS (typical), ≤±1.0% FS (maximum) |
|
Measurement Range |
Liquid: 2.5 ~ 1,000,000 L/h; Gas: 0.07 ~ 3,000 m³/h |
|
Maximum Process Pressure |
DN15, DN25, DN50: 4.0 MPa; DN80, DN100, DN150: 1.6 MPa |
|
Medium Temperature Range |
Standard type: -30℃ ~ +120℃; High temperature type: 120℃ ~ 350℃; PTFE lined: up to 80℃ |
|
Ambient Temperature Range |
On-site type: -40℃ ~ 120℃; Remote type: -30℃ ~ 70℃ |
|
Transmitter Housing Material |
Carbon steel or stainless steel (optional depending on the model) |
|
Display/Operation |
Provides 0-10mA and 4-20mA local indication, supports accumulation, digital communication, and field modification of measurement parameters |
|
Inputs |
Analog Input |
|
Outputs |
Two-wire: 4-20mA DC, |
|
Power Supply |
24VDC (12~36VDC); Lithium battery power supply; 220VAC |
|
Certificate |
CE Certification; Protection Level IP65; Explosion-proof type available (option) |
|
Functional Safety |
Ex ia IIC T1~T4 Ga |
Hot Tags: metal tube flow meter, China metal tube flow meter manufacturers, suppliers, factory, 2 turbine flow meter, Compact turbine flow meter, Diesel turbine flow meter, magnetic flow meter transmitter, Thermal Air Flow Sensor, turbine meter gas